Deltadrive DC drives are available in four frame sizes up to 450kW, with a choice of two or four quadrant operation and with the option of a unique electronic regenerative stopping facility on the two-quadrant versions.
Steady state accuracy is typically 0.01% when used in conjunction with an
encoder and digital reference, 0.1% with tacho and 2% with AVF.
Up to 99 macro modes may be stored in the drive to be recalled at a later
time, making for easy interchangeability.
The I/O provision with Deltadrive has to be seen to be believed!
As standard, the Deltadrive comes with a wealth of I/O available: 8 Universal
inputs, configurable as digital inputs or analogue inputs with ±5V, 10V, 20V or
30V as required; 4 additional analogue outputs, 4 digital inputs, 3 digital
outputs; an additional 4 digital I/O which can be configured as either inputs or
outputs depending on the application requirements.
The versatility doesn't end there. The drive can be configured to run two
different motors, or two sets of parameters for the same motor. This can be very
useful, for example, in crane and hoist applications.
Diagnostics include: fault latch and auto display, digital monitoring via
display, full diagnostics via RS232 and digital and relay status display. There
are comprehensive system alarms with descriptive annunciation.
The operator unit comprises a simple 4-button tactile keypad with a
40-character back-lit LCD. There are multi- language options and security of the
operating procedure is maintained by password protection. Deltadrive DC drives
comply with all relevant quality standards and safety regulations relating to
installation and operation, including compliance with the requirements of EU
guidelines governing electromagnetic compatibility. All Deltadrives bear the CE
symbol.
I/O provision as
standard: 8 Analogue inputs & 4 Analogue
outputs All Analogue inputs programmable voltage range up to +/- 30V 17
Digital inputs & 7 Digital outputs All Analogue & Digital outputs
short circuit protected All Analogue inputs & Digital inputs and outputs
are over-voltage protected
Speed
Feedback options : Analogue tacho Encoder Armature
voltage Encoder + Armature voltage Encoder + Analogue
tacho
Standard
Software functions : Full suite of centre winding
macros Motorised pot simulator Two undedicated PID's Two undedicated
Summers Delay Timer Current Profiling Zero speed lock Jog / Crawl
functions Two undedicated filters Dual motor swap Latch Auto
self-tune current loop Linear- or S- ramp Slack take up Batch
counter Draw control
|
 |
Diagnostic
Monitoring : All analogue input and output
voltages All digital input and output states Tacho volts Motor armature
current ( amps ) Motor field current ( amps ) Motor armature
volts Output power kW AC supply volts
Protection
: Interline device networks High energy MOV's Instantaneous
overcurrent Overcurrent ( 150% for 25s inverse time ) Field Failure &
Overcurrent Motor over-temperature Thyristor stack
over-temperature Mains supply phase loss Mains
synchronisation loss Armature overvolts Overspeed Speed feedback
mismatch Stall protection Standstill logic Thyristor 'trigger'
failure Digital output short circuit
Field
configurations : Fixed Current or Voltage Field Weakening Delayed
Quenching Standby field value Field Economy |
Key features
- Motor power control from 5.0kW to 450kW
- Four chassis variants, each with 2 or 4-quadrant versions available
- Unique electronic stopping facility on selected 2-Q models
- Extensive programmable I/O
- Large back-lit alphanumeric LCD display of text (40 characters)
- 4-button tactile keypad is easy to use
- Wealth of built-in system blocks to aid commissioning
- PC or off-site programming via RS232 serial communications
- Master/slave configurations easy to set-up using RS232
- Choice of in-line or DC link choke for power factor correction
- In-depth fault monitoring - off-site diagnostics via RS232
- Wide range of application macros
- Integral field controller
- Minimum panel width requirement
- Multi-language display
Technical Data & Dimensions
Model
DD=2 quadrant
DDX=4 quadrant |
kW
(460V) |
HP
460V |
Armature
Current
DC A |
Field
amps |
Dimensions
HxWxD
(mm) |
| DD and DDX |
12 |
5 |
6.6 |
12 |
8.0 |
289x216x174 |
| DD and DDX |
24 |
10 |
13.3 |
24 |
8.0 |
" |
| DD and DDX |
36 |
15 |
20 |
36 |
8.0 |
" |
| DD and DDX |
48 |
20 |
26.6 |
48 |
8.0 |
" |
| DD and DDX |
72 |
30 |
40 |
72 |
8.0 |
" |
| DD and DDX |
96 |
40 |
53.3 |
96 |
8.0 |
" |
| DD and DDX |
120 |
50 |
66.6 |
120 |
8.0 |
" |
| DD and DDX |
155 |
65 |
90 |
155 |
16.0 |
378x216x218 |
| DD and DDX |
205 |
85 |
115 |
205 |
16.0 |
" |
| DD and DDX |
270 |
115 |
155 |
270 |
16.0 |
" |
| DD and DDX |
330 |
145 |
190 |
330 |
16.0 |
" |
| DD and DDX |
430 |
185 |
250 |
430 |
32.0 |
376x216x294 |
| DD and DDX |
530 |
225 |
300 |
530 |
32.0 |
" |
| DD only |
630 |
265 |
350 |
630 |
32.0 |
" |
|