The SFD soft start - Features:
- Input 400-460V 3-Phase (-15% +10%) 50/60Hz +/- 2Hz
- Smooth acceleration
- Reduced starting torque decreases mechanical stress
- Suitable for all types of 3 phase induction motors
- Select from pre-programmed soft start profiles
- Kick start option for high break-away torque loads
- Soft stop to give controlled deceleration
- Over-current "shear pin" protection
- Reduction of motor starting current
- Phase loss protection at starting
- Top of ramp and run relays
- Multi ramp starting and stopping strategies
- Enclosure IP20 Din Rail or IP43
The SFD soft start - Ratings:
| Model Type |
Motor FLC
(amps) |
Motor Power @ |
| 400V (kW) |
460V (kW) |
| SFD 5 IP20 |
SFD 5 IP43 |
5 |
2.2 |
2.2 |
| SFD 9 IP20 |
SFD 9 IP43 |
9 |
4.0 |
4.0 |
| SFD 16 IP20 |
SFD 16 IP43 |
16 |
7.5 |
7.5 |
| SFD 23 IP20 |
SFD 23 IP43 |
23 |
11 |
11 |
| SFD 30 IP20 |
SFD 30 IP43 |
30 |
15 |
15 |
| SFD 44 IP20 |
SFD 44 IP43 |
44 |
22 |
22 |
| SFD 59 IP20 |
SFD 59 IP43 |
59 |
30 |
30 |
| SFD 72 IP20 |
SFD 72 IP43 |
72 |
37 |
40 |
| SFD 90 IP20 |
|
90 |
45 |
45 |
The QFD soft start - Features:
- Inputs available are 230-460V and 500-690V 50/60Hz
- Continuous display of motor current & control status
- Easily changed parameter settings via the keypad
- User adjustable overload
- Last 5 trips recorded
- 110/230V control supply
- User selectable built-in application specific settings
- Isolated control inputs - 24V DC, 110/230V AC for start/stop or user programmable
- Current limit time out - optional trip or continue
- Undercurrent trip level and delay: 0-1 x FLC
- Adjustable starting current limit control
- Separately adjustable ramp up/down times from 1 to 240 seconds
- Adjustable kick start for high breakaway torque applications
- Fully adjustable pedestal voltage
- User adjustable shear pin
- Control of resistive loads
- In Delta operation
- Thermistor trip input
- 4-20mA input monitoring
- DC input for monitoring
- Communications
- IP20 rating
- Peak starting current recording
- Adjustable optimising response rate
The SFD soft start - Ratings: Size 1
Model
Type |
Motor FLC
(amps) |
- - - - - Motor Power - - - - - |
@230V (kW) |
@400V (kW) |
@460V (kW) |
@575V (kW) |
@690V (kW) |
| QFD 9 |
9 |
2.2 |
4 |
4 |
5.5 |
7.5 |
| QFD 16 |
16 |
3.7 |
7.5 |
7.5 |
11 |
15 |
| QFD 23 |
23 |
6.3 |
11 |
11 |
15 |
22 |
| QFD 30 |
30 |
7.5 |
15 |
15 |
22 |
30 |
| QFD 44 |
44 |
11 |
22 |
22 |
30 |
37 |
| QFD 59 |
59 |
16 |
30 |
32 |
37 |
55 |
| QFD 72 |
72 |
20 |
37 |
40 |
45 |
60 |
| QFD 85 |
85 |
22 |
45 |
45 |
55 |
75 |
| QFD 105 |
105 |
30 |
55 |
55 |
75 |
90 |
| QFD 146 |
146 |
45 |
75 |
80 |
110 |
132 |
The SFD soft start - Ratings: Size 2
Model
Type |
Motor FLC
(amps) |
- - - - - Motor Power - - - - - |
@230V (kW) |
@400V (kW) |
@460V (kW) |
@575V (kW) |
@690V (kW) |
| QFD 174 |
174 |
55 |
90 |
110 |
132 |
160 |
| QFD 202 |
202 |
63 |
110 |
132 |
150 |
200 |
| QFD 242 |
242 |
75 |
132 |
150 |
185 |
220 |
| QFD 300 |
300 |
90 |
160 |
185 |
220 |
300 |
| QFD 370 |
370 |
110 |
200 |
220 |
250 |
375 |
The SFD soft start - Ratings: Size 3
Model
Type |
Motor FLC
(amps) |
- - - - - Motor Power - - - - - |
@230V (kW) |
@400V (kW) |
@460V (kW) |
@575V (kW) |
@690V (kW) |
| QFD 500 |
500 |
160 |
250 |
300 |
375 |
500 |
| QFD 600 |
600 |
185 |
320 |
375 |
450 |
600 |
| QFD 750 |
750 |
250 |
400 |
450 |
560 |
750 |
| QFD 900 |
900 |
300 |
500 |
560 |
670 |
900 |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |